{"id":2119,"date":"2025-06-13T06:51:42","date_gmt":"2025-06-13T06:51:42","guid":{"rendered":"https:\/\/qibrit.com\/innovare\/?page_id=2119"},"modified":"2025-06-13T06:53:10","modified_gmt":"2025-06-13T06:53:10","slug":"en-1149","status":"publish","type":"page","link":"https:\/\/qibrit.com\/innovare\/en-1149\/","title":{"rendered":"EN 1149"},"content":{"rendered":"<section class=\"wpb-content-wrapper\"><p>[vc_row][vc_column][vc_column_text]<\/p>\n<h4>EN 1149 \u2013 Protection Against Electrostatic Discharge<\/h4>\n<p>[\/vc_column_text][vc_column_text]<strong>Overview<\/strong><br \/>\nEN 1149 is a multi-part standard that specifies test methods and performance requirements for protective clothing and fabrics designed to prevent electrostatic discharge. This type of protection is essential in environments where flammable gases, vapors, powders, or dusts are present\u2014such as fuel handling, chemical manufacturing, pharmaceuticals, and grain processing facilities. In these settings, a small static spark can be enough to ignite an explosive atmosphere.<\/p>\n<p>EN 1149 consists of several parts that apply to different aspects of electrostatic behavior. For fabric manufacturers, the most relevant parts are EN 1149-1, EN 1149-2, and EN 1149-3. These methods test whether a fabric can safely dissipate electrostatic charges. EN 1149-5 is the performance standard used at the garment level, which requires the fabric to meet one or more of the mentioned test methods.<\/p>\n<p><strong>Testing Methods &amp; Minimum Performance Levels<\/strong><\/p>\n<table width=\"642\">\n<tbody>\n<tr>\n<td width=\"132\"><strong>Test Method<\/strong><\/td>\n<td width=\"293\"><strong>Description<\/strong><\/td>\n<td width=\"217\"><strong>Requirements<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"132\"><strong>EN 1149-1 <\/strong><\/td>\n<td width=\"293\"><strong><em>Surface Resistivity Method<\/em><\/strong><em><br \/>\n<\/em>Measurement of surface electrical resistance:This method evaluates the ability of a fabric to allow static electricity to dissipate along its surface.<\/td>\n<td width=\"217\">\n<ul>\n<li>Surface resistivity \u2264 2.5 \u00d7 10\u2079 \u03a9<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"132\"><strong>EN 1149-2<\/strong><\/td>\n<td width=\"293\">\n<p><strong><em>Vertical Resistance Method<\/em><\/strong><\/p>\n<p>Measurement of vertical (through-thickness) resistance:<br \/>\nMeasures how charges pass through the thickness of the fabric-from the outer surface to the skin-facing side.<\/p>\n<p><strong><em>\u00a0<\/em><\/strong><\/td>\n<td width=\"217\">\n<ul>\n<li><strong>Vertical resistance \u2264 1 \u00d7 10\u2079 \u03a9<\/strong><\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"132\"><strong>EN 1149-3<\/strong><\/td>\n<td width=\"293\"><strong><em>Charge Decay Test<\/em><\/strong><strong><br \/>\n<\/strong>Time-based measurement of charge dissipation:This optional method determines how quickly a fabric dissipates an electrostatic charge once the source is removed<\/td>\n<td width=\"217\"><strong>\u00a0<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"132\"><strong>EN 1149-5<\/strong><\/td>\n<td width=\"293\">\n<p><strong><em>Performance Requirements for Garments<\/em><\/strong><\/p>\n<p>Defines garment-level compliance<\/p>\n<p><strong><em>\u00a0<\/em><\/strong><\/td>\n<td width=\"217\">\n<ul>\n<li>To meet EN 1149-5, a protective garment must be made from materials that comply with EN 1149-1 or EN 1149-2, and be designed to ensure effective dissipation of electrostatic charges. It also requires proper grounding during use and full-body coverage.<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<h4><strong>Additional Mechanical &amp; Dimensional Tests<\/strong><\/h4>\n<table width=\"642\">\n<tbody>\n<tr>\n<td width=\"132\"><strong>Test Method<\/strong><\/td>\n<td width=\"293\"><strong>Description<\/strong><\/td>\n<td width=\"217\"><strong>Requirements<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"132\"><strong>ISO 5077<\/strong><\/td>\n<td width=\"293\"><strong><em>Dimensional Stability to Washing<\/em><\/strong><br \/>\nDetermines shrinkage or growth of the fabric after domestic laundering.<\/td>\n<td width=\"217\">\n<ul>\n<li>Shrinkage should not exceed \u00b13% (woven)<\/li>\n<\/ul>\n<p>\u00b15% (knitted)<\/td>\n<\/tr>\n<tr>\n<td width=\"132\"><strong>ISO 13934-1 <\/strong><\/td>\n<td width=\"293\"><strong><em>Tensile Strength (Strip Method)<\/em><\/strong><br \/>\nMeasures the maximum force needed to break a strip of fabric in warp and weft directions.<\/td>\n<td width=\"217\">\n<ul>\n<li>Warp: \u2265 400 N<\/li>\n<li>Weft: \u2265 400 N<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"132\"><strong>ISO 13937-2 <\/strong><\/td>\n<td width=\"293\">\n<p><strong><em>Tear Strength (Wing Method)<\/em><\/strong><\/p>\n<p>Evaluates resistance to tearing using a trapezoidal-shaped cut and applying load to propagate it.<\/td>\n<td width=\"217\">\n<ul>\n<li>\u2265 20 N (warp and weft)<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"132\"><strong>ISO 13938-1 <\/strong>Hydraulic Method<\/td>\n<td width=\"293\"><strong><em>Bursting Strength<\/em><\/strong><br \/>\nTests bursting strength using a hydraulic system.<\/td>\n<td width=\"217\">\n<ul>\n<li>\u2265 200 kPa<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"132\"><strong>ISO 13938-2 <\/strong>Pneumatic Method<\/td>\n<td width=\"293\"><strong><em>Bursting Strength<\/em><\/strong><br \/>\nSimilar to 13938-1 but uses compressed air (pneumatic pressure) instead of liquid.<\/td>\n<td width=\"217\">\n<ul>\n<li>\u2265 200 kPa<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4><strong>\u00a0<\/strong><strong>Industries <\/strong><\/h4>\n<ul>\n<li>Oil, Gas and Petrochemical Industry<\/li>\n<li>Electric and Utility Services<\/li>\n<li>Chemical Industry<\/li>\n<li>Railways and Transportation<\/li>\n<li>Construction and Heavy Industry<\/li>\n<li>Maritime and Offshore<\/li>\n<li>Industrial FR Workwear<\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n<\/section>","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_column_text] EN 1149 \u2013 Protection Against Electrostatic Discharge [\/vc_column_text][vc_column_text]Overview EN 1149 is a multi-part standard that specifies test methods and performance requirements for protective clothing and fabrics designed to prevent electrostatic discharge. This type of protection is essential in environments where flammable gases, vapors, powders, or dusts are present\u2014such as fuel handling, chemical manufacturing, pharmaceuticals, &hellip; <a href=\"https:\/\/qibrit.com\/innovare\/en-1149\/\" class=\"more-link\">Continue reading <span class=\"screen-reader-text\">EN 1149<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"pagelayer_contact_templates":[],"_pagelayer_content":"","footnotes":""},"class_list":["post-2119","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/qibrit.com\/innovare\/wp-json\/wp\/v2\/pages\/2119","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/qibrit.com\/innovare\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/qibrit.com\/innovare\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/qibrit.com\/innovare\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/qibrit.com\/innovare\/wp-json\/wp\/v2\/comments?post=2119"}],"version-history":[{"count":3,"href":"https:\/\/qibrit.com\/innovare\/wp-json\/wp\/v2\/pages\/2119\/revisions"}],"predecessor-version":[{"id":2122,"href":"https:\/\/qibrit.com\/innovare\/wp-json\/wp\/v2\/pages\/2119\/revisions\/2122"}],"wp:attachment":[{"href":"https:\/\/qibrit.com\/innovare\/wp-json\/wp\/v2\/media?parent=2119"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}